Add to Cart
FCAW E309LT1-1 1.2/1.4/1.6mm CO2 Gas Shielded Stainless Steel Flux Cored Arc Welding Wire
Designed for welding type 309 wrought, or cast forms, but used extensively for welding type 304 to mild or carbon steel. Also used for welding 304 clad sheets and for applying stainless steel sheet linings to carbon steel. Following the chemical composition designation comes the letter “T” which signifies that the product is a flux cored electrode or rod. Following the “T” is a “1” or “0” indicating the recommended position of welding. The “1” or “0” following the “T” designates the following: “0” – designed to weld in the flat or horizontal position, “1” – designed to weld in all position. Following the position indicator and a dash, are the numerals “1”, “3”, “4”, “5”, or the letter “G”. The numerals “1”, “4”, and “5” identify the shielding gas required for classification of the electrode. The number “3” signifies that an external shielding gas is not employed. The letter “G” signifies that the shielding medium, chemical composition and mechanical properties are not specified.
FCAW LT·309L
Conform to Standard :GB/T 17853 E309LT1-1
AWS A5.22 E309LT1-1
Shielding Gas:CO2
Chemical Composition(%)(Shielding Gas:CO2)
Chemical Composition | C | Mn | Si | Ni | Cr | S | P |
Guarantee Value | ≤0.04 | 0.50~2.50 | ≤1.00 | 12.0~14.0 | 22.0~25.0 | ≤0.030 | ≤0.040 |
General Result | 0.035 | 1.25 | 0.58 | 12.4 | 24.15 | 0.004 | 0.023 |
Mechanical Properties of Deposited Metal(Shielding Gas:CO2)
Test Item | Rm(MPa) | A(%) |
Guarantee Value | ≥520 | ≥25 |
General Result | 560 | 41.5 |
Specification of supply:Φ1.2mm Φ1.4mm Φ1.6mm